Ndle2 (NFIN) Residual Current Operated Circuit-Breakers (RCCBS)
Basic Info
Model No.: NDLE2(NFIN)
Product Description
Model NO.: NDLE2(NFIN) Operation: Electric Type Arc-extinguishing Medium: Oil-immersed Type Structure: ELCB Type: Circuit Breaker Certification: ISO9001-2000, CE Origin: Wenzhou, Zhejiang Breaking Capacity: Low Voltage Circuit Breakers Speed: Normal Type Circuit Breaker Installation: Fixed Poles Number: 4 Function: Overcurrent Protection Trademark: onandoff or oem HS Code: 8536200000 NDLE2(NFIN)Residual Current operated Circuit-Breakers (RCCBS) Application
The Residual Current operated Circuit-Breakers (RCCBs) of the AC type adapted to domestic, public, and industrial fields are used in the distribution systems TT, TN, and IT in accordance with the rules and regulations in force. The RCCBs together with the earthing system are therefore used to protect people in case of indirect contacts. These devices characterized by a rated residual differential current of 30mA also assure an additional protection in case of direct contacts. In addition to the function of protection against direct or indirect contacts, the Residual Current operated Circuit-Breakers (RCCBs) incorporate a protective function against the danger of fire in the event of insulation breakdown.
Classification
--- AC type: Residual Current operated Circuit-Breakers (RCCBs) for AC fault currents;
--- A type: Residual Current operated Circuit-Breakers (RCCBs) for AC and pulsating DC fault currents, offering a high resistance to surge current pluses;
--- B type: Residual Current operated Circuit-Breakers (RCCBs) for AC, pulsating DC and smooth DC fault currents. Technical Data
--- AC type Residual Current operated Circuit-Breakers (RCCBs) for AC currents type: AC
--- Rated residual fault currents I△n:30mA,100mA, 300mA;500mA
--- Rated residual non-operating currents I△no:15mA, 50mA, 150mA,250mA
--- Rated current In:16,25,40,63,80A
--- Rated voltage Un: AC 125V-230V(2P),AC 230V-400V(4P)
--- Rated differential breaking capacity Im:800A,
--- Resistance to surge current pulsed-lightning or switchgear manipulation-according to IEC 1008-1
--- Compliance with the standards: IEC 1008-1,EN61008-1,GB16916-1
--- Tripping time I△n T Contact us if you need more details on ELCB. We are ready to answer your questions on packaging, logistics, certification or any Other aspects about MCB、ELCB. If these products fail to match your need, please contact us and we would like to provide relevant information.
The Residual Current operated Circuit-Breakers (RCCBs) of the AC type adapted to domestic, public, and industrial fields are used in the distribution systems TT, TN, and IT in accordance with the rules and regulations in force. The RCCBs together with the earthing system are therefore used to protect people in case of indirect contacts. These devices characterized by a rated residual differential current of 30mA also assure an additional protection in case of direct contacts. In addition to the function of protection against direct or indirect contacts, the Residual Current operated Circuit-Breakers (RCCBs) incorporate a protective function against the danger of fire in the event of insulation breakdown.
Classification
--- AC type: Residual Current operated Circuit-Breakers (RCCBs) for AC fault currents;
--- A type: Residual Current operated Circuit-Breakers (RCCBs) for AC and pulsating DC fault currents, offering a high resistance to surge current pluses;
--- B type: Residual Current operated Circuit-Breakers (RCCBs) for AC, pulsating DC and smooth DC fault currents. Technical Data
--- AC type Residual Current operated Circuit-Breakers (RCCBs) for AC currents type: AC
--- Rated residual fault currents I△n:30mA,100mA, 300mA;500mA
--- Rated residual non-operating currents I△no:15mA, 50mA, 150mA,250mA
--- Rated current In:16,25,40,63,80A
--- Rated voltage Un: AC 125V-230V(2P),AC 230V-400V(4P)
--- Rated differential breaking capacity Im:800A,
--- Resistance to surge current pulsed-lightning or switchgear manipulation-according to IEC 1008-1
--- Compliance with the standards: IEC 1008-1,EN61008-1,GB16916-1
--- Tripping time I△n T Contact us if you need more details on ELCB. We are ready to answer your questions on packaging, logistics, certification or any Other aspects about MCB、ELCB. If these products fail to match your need, please contact us and we would like to provide relevant information.
Product Categories : Circuit Breaker
Premium Related Products
Other Products
Hot Products
Prwg-35u Drop Cut-out FuseSeries CableSeries Knife SwitchControl Stations PushbuttonsAuto Transformers (QZB Series) (QZB-30)Automatic Voltage Stabilizer Tnd/Tns SeriesTgm30L (ELCB)JMB 25va~10kva/25w~10kw single phase control transfomer 380v/240v/220v/110vJBK5 Single phase Machine tool control TransformerPure sine wave solar Power inverter 800w2014 HOT Sale Low voltage capacitor series connection CKSG ModelWenzhou SG three phase Power Voltage TransformerHot SVR 12KVA Wall Mounted AC Servo Motor Single Phase Automatic Home Voltage Stabilizer For ComputerAKSDQ Wholesale SVC 10000VA Single Phase Automatic Home Voltage Stabilizer Regulator Wenzhou Yueqing FactoryTS Convert power supply 220/240V Transformer 1000W,2000W,3000WHot Selling Product 3 Phase Servo Full Automatic Compensated Power Voltage Stabilizer or Regulator 500kva for Hospital Yueqing